Installation - Mechanical
CLCH-SVX07C-EN 31
14. Install the section-to-section screws inserting the
appropriate screws through the overlapping flanges
using a powered impact gun and taking care not to
strip the screws. Outdoor air handlers will ship with a
seam cap that is to be installed over the section-to-
section seams. Factory-supplied butyl tape must be
applied over the seam prior to seam cap being applied.
See Figure 30.
15. For outdoor air handlers, attach roof overhang angle
with number 10 screws. Join outdoor roof panels
together at the seams in the direction perpendicular to
airflow and secure them in place with 5/16-inch x 3/4-
inch bolts and 5/16 lock nuts. Install the roof joint strip
to cover the seam between two outdoor roof panels in
the perpendicular to airflow direction of. Use 3/8-inch
butyl tape to cover the seam between two outdoor roof
panels overhang at the side the unit. Bend joint strip
over roof panel and use two number 10 sheet metal
screws (one in each roof panel) to secure joint strip.
Trim the roof joint strip to insure that it does not
protrude more than 1/16-inch beyond outdoor roof
overhang (see Figure 31).
Figure 30. Section-to-section seam cap installation
Seam cap
Butyl tape
Detail A
See
Detail A
See
Detail B
Detail B
Roof overhang
Butyl tape